Product

Contact us

Shandong Qingneng Steam Turbine Co.,Ltd.

Tel: +86-536-3290518
Fax: +86-536-3291618
E-mail: info@qnpturbine.com
ADD: No.3011 Haidai North Road,Qingzhou City, Shandong Province, China


Condensing Steam Turbine

 

Air-cooled steam turbine can be designed according to customer's needs.

Product characteristics:

Maximum inlet steam pressure: 14Mpa

Maximum inlet steam temperature: 535℃

Maximum capacity: 200MW

With a non-controlled(bleed) extraction steam outlet to meet small amount of steam demand.

Injection steam inlet can be added to fully utilize low quality steam (including saturated steam).

Exhaust steam can be cooling by water-cooling or air-cooling system.

Can be used for power generating or driving other equipment.

Customized order

Remote monitoring and diagnose service

Applicable to geothermic power generating

 
Parameter:

NO.ModelCapacity(MW)  InletExhaustPressure(Mpa) Speed(r/min)  
PressureTemp
(MPa)(℃)
1N0.5~N1.60.5~1.6≤3.0≤4000.0086500
2N1~N41~41.2~4250~4400.01035600
3N3~N63~61.2~3.2250~4400.00983000
4N4~N7.54~7.52.3~4.5350~4700.00813000
5N8~N108~102.3~4.5350~4700.00613000
6N10~N1510~152.3~5350~4700.00753000
7N12~N1512~156.5~10435~5350.00613000
8N15~N2015~202.3~5350~4700.01043000
9N15~N2015~206.5~10435~5350.00493000
10N20~N3020~302.3~5350~4700.00653000
11N20~N3020~306.5~10435~5350.00493000
12N35~N6035~603.4~5400~4700.00493000
13N40~N6040~606.5~10435~5350.00493000
14N80~N10080~1006.5~10470~5350.00493000
15N125-13.24/535/53512513.245350.0053000
16N150-13.24/535/53515013.245350.0053000
17N200-13.24/535/53520013.245350.0053000
18N300-16.7/537/53730016.75370.0053000

 

 

 

next: There is not!Back Pressure Steam Turbine :Previous